Load Cell Configuration Register

Type:

Axis Parameter Register

Address:

RMC70: n/a

RMC150: n/a

RMC200:

Primary Input: %MDn.60, where n = 384 + the axis number

Secondary Input: %MDn.120, where n = 384 + the axis number

System Tag:

Primary Input: _Axis[n].LoadCellCfg

Secondary Input: _Axis[n].SecLoadCellCfg

where n is the axis number

How to Find:

See individual parameter registers listed below

Data Type:

DWORD

Description

The Load Cell Configuration Register contains the bit-addressable feedback configuration parameters for load cell inputs. This topic lists the bit address for each parameter. Each parameter is accessible in RMCTools via the Axis Parameter Editor. For details on each parameter, see the respective links.

Changing this Parameter Register

Because this parameter register affects motion, the axis must be disabled or in Direct Output before writing to this register. The Enabled and Direct OutputStatus Bits indicate these states of the axis. When changing this parameter from RMCTools, the software will automatically do this for you. This may cause a halt on the axis, which is expected.

Bits

This register contains the following parameters. The bits for each are given in the right-hand column.

RMC200

Parameter

Tag Name

Bit Number(s)

Exciter Mode

Exciter Mode

0-3

 

Note:
For details on the values that each bit represents, see the respective parameter topic.

 

 

See Also

Parameter Registers


Send comments on this topic.

Copyright © 2025 Delta Computer Systems, Inc. dba Delta Motion