Pressure/Force Offset

Type:

Axis Parameter Register

Address:

RMC75:

Primary Input: %MDn.1, where n = 12 + the axis number

Secondary Input: %MDn.19, where n = 12 + the axis number

RMC150:

Primary Input: %MDn.1, where n = 24 + the axis number

Secondary Input: %MDn.19, where n = 24 + the axis number

RMC200:

Primary Input: %MDn.21, where n = 384 + the axis number

Secondary Input: %MDn.81, where n = 384 + the axis number

System Tag:

Pressure Input: _Axis[n].PrsOffset

Force Input: _Axis[n].FrcOffset

where n is the axis number

How to Find:

Axes Parameters Pane, Setup tab: Primary Control Setup

Axes Parameters Pane, Setup tab: Secondary Control Setup

Data Type:

REAL

Units:

Pr or Fr

Range:

any

Default Value:

0

Description

The Pressure Offset or Force Offset parameter is used together with the Pressure Scale or Force Scale parameter to calculate the Actual Force or Actual Pressure from the voltage or current of the input.

The Offset is added to the scaled Pressure or Force.

On the RMC200:

Changing this Parameter

Because this parameter affects motion, the axis must be disabled or in Direct Output before writing to this parameter. The Enabled and Direct OutputStatus Bits indicate these states of the axis. When changing this parameter from RMCTools, the software will automatically do this for you. This may cause a halt on the axis, which is expected.

 

See Also

Parameter Registers | Analog Pressure/Force Scaling